| Technische Daten PWR-SPLY-5V3A-MG | |
|---|---|
| AC Input | 100-240Vac, -/-10%, 47-63 Hz, 10 |
| Input Current | 100Vac: 0.45A |
| Inrush Current | Inrush limiting provided, 60 A peak |
| Input Fuse | Internal Primary Current Fuse provided: 3,15A, 250Vac |
| Efficiency | Meets EISA2007, CEC Efficiency Level V, EU (EC) No 278/2009 Phase II |
| Output Voltage | 5V DC |
| Output Power | 3,00 A |
| Ripple and Noise | 1% pk-pk max., 20MHz BW |
| Line & Load Voltage Regulation | Line: +/- 1%, Load: +/-5% |
| Minimum Load | Not required |
| Transient Response | 500 us max, 50% load step |
| Case Dimensions | 84 X 47 X 32mm |
| Case Material | Black 94VO Polycarbonate |
| Weight | 150g |
| MTBF | 100,000 hours (calculated) |
| Hold-up Time | 18 ms min. @ 115Vac, 60 ms min. @ 230 Vac |
| Overload Protection | Hiccup Mode |
| Short Circuit Protection | Hiccup Mode |
| Topology | Switching - Fixed Frequency Flyback |
| Safety Standards | EN/IEC/CSA/UL60601 -1 |
| EMC, Radiated & Conducted | See chart below |
| Dielectric Withstand | Input-Output: 5,656VDC, Input-Ground: 1,500Vac, Output-Ground: 500Vdc |
| Operating Temperature | 0° to 40°C , no derating |
| Storage Temperature | -30 to +85°C |
| Relative Humidity | 5% to 95%, non-condensing |
| Altitude | 0 lo 10,000 ft |
| Turn-on Time | 2 sec max, 115/230 Vac |
| Output Cable | #18AWG (SPT-1 ), 1500mm, 2 conductor |
| Output Connector | 2,5mm barrel type (Aull #3), cenler contact(+) |
| EMC Specifications | |
|---|---|
| Conducted Emissions | EN55011 Class B, FCC Part 15, Class B. |
| Radiated Emissions | EN55011 Class B, FCC Part 15, Class B. |
| Line Frequency Harmonics | EN61000-3-2, Class A |
| Voltage Fluctuations/Flicker | EN61000-3-3 |
| Static Discharge Immunity | EN61000-4-2, 6kV Contact Discharge, 8kV air discharge |
| Radiated RF Immunity | EN61000-4-3, 3V/m. |
| EFT/Burst Immunity | EN61000-4·4, 2kV/5kHz. |
| Line Surge Immunity | EN61000-4-5, 1 kV differential, 2kV common-mode |
| Conducted RF Immunity | EN61000-4-6, 3Vrms |
| Power Frequency Magnetic Field Immunity | EN61000-4-8, 3A/m |
| Voltage Dip Immunity | EN61 000-4-11 , Criteria A |
| Technische Daten PWR-SPLY-5V3A-MG | |
|---|---|
| AC Input | 100-240Vac, -/-10%, 47-63 Hz, 10 |
| Input Current | 100Vac: 0.45A |
| Inrush Current | Inrush limiting provided, 60 A peak |
| Input Fuse | Internal Primary Current Fuse provided: 3,15A, 250Vac |
| Efficiency | Meets EISA2007, CEC Efficiency Level V, EU (EC) No 278/2009 Phase II |
| Output Voltage | 5V DC |
| Output Power | 3,00 A |
| Ripple and Noise | 1% pk-pk max., 20MHz BW |
| Line & Load Voltage Regulation | Line: +/- 1%, Load: +/-5% |
| Minimum Load | Not required |
| Transient Response | 500 us max, 50% load step |
| Case Dimensions | 84 X 47 X 32mm |
| Case Material | Black 94VO Polycarbonate |
| Weight | 150g |
| MTBF | 100,000 hours (calculated) |
| Hold-up Time | 18 ms min. @ 115Vac, 60 ms min. @ 230 Vac |
| Overload Protection | Hiccup Mode |
| Short Circuit Protection | Hiccup Mode |
| Topology | Switching - Fixed Frequency Flyback |
| Safety Standards | EN/IEC/CSA/UL60601 -1 |
| EMC, Radiated & Conducted | See chart below |
| Dielectric Withstand | Input-Output: 5,656VDC, Input-Ground: 1,500Vac, Output-Ground: 500Vdc |
| Operating Temperature | 0° to 40°C , no derating |
| Storage Temperature | -30 to +85°C |
| Relative Humidity | 5% to 95%, non-condensing |
| Altitude | 0 lo 10,000 ft |
| Turn-on Time | 2 sec max, 115/230 Vac |
| Output Cable | #18AWG (SPT-1 ), 1500mm, 2 conductor |
| Output Connector | 2,5mm barrel type (Aull #3), cenler contact(+) |
| EMC Specifications | |
|---|---|
| Conducted Emissions | EN55011 Class B, FCC Part 15, Class B. |
| Radiated Emissions | EN55011 Class B, FCC Part 15, Class B. |
| Line Frequency Harmonics | EN61000-3-2, Class A |
| Voltage Fluctuations/Flicker | EN61000-3-3 |
| Static Discharge Immunity | EN61000-4-2, 6kV Contact Discharge, 8kV air discharge |
| Radiated RF Immunity | EN61000-4-3, 3V/m. |
| EFT/Burst Immunity | EN61000-4·4, 2kV/5kHz. |
| Line Surge Immunity | EN61000-4-5, 1 kV differential, 2kV common-mode |
| Conducted RF Immunity | EN61000-4-6, 3Vrms |
| Power Frequency Magnetic Field Immunity | EN61000-4-8, 3A/m |
| Voltage Dip Immunity | EN61 000-4-11 , Criteria A |