ADVANTECH ADAM-6066
6 digitale Eingänge, 6 Relaisausgänge (AC: 250V@5A, DC:30V@5A)
ADAM-6066’s six digital output channels are designed for 240 V AC, 5 A ratings, and support both dry contact and pulse output. Besides, ADAM-6066 has an embedded web server for remote monitoring, supports Modbus/TCP and UDP protocol to meet standard communication requirements, and offers personalized settings for improved flexibility. Its watchdog timer and host idle functions secure communication for reliable operation.
- General
- LAN 10/100Base-T(X)
- Power Consumption 2.5 W @ 24 VDC
- Connectors 1 x RJ-45 (LAN), Plug-in screw terminal block (I/O and power)
- Watchdog Timer System (1.6 second) and Communication (programmable)
- Power Input 10 ~ 30 VDC
- Supports Peer-to-Peer
- Supports GCL
- Supports Modbus/TCP, TCP/IP, UDP and HTTP Protocols
- Digital Input
- Channels 6
- Dry Contact Logic level 0: close to GND
- Logic level 1: open
- Wet Contact Logic level 0 ~ 3 VDC
- Logic level 1: 10 ~ 30 VDC
- Supports 3 kHz Counter Input (32-bit + 1-bit overflow)
- Keep/Discard Counter Value when Power-off
- Supports 3 kHz Frequency Input
- Supports Inverted DI Status
- Relay Output (Form A)
- Channels 6
- Contact Rating (Resistive): 250 V @ 5 A (AC)
- 30 V @ 5 A (DC)
- Breakdown Voltage 500 VAC (50/60 Hz)
- Relay On Time 7 ms
- Relay Off Time 3 ms
- Total Switching Time 10 ms
- Insulation Resistance 1 GΩ min. at 500 VDC
- Maximum Switching 20 operations/minute
- Rate (at rated load)
- Supports Pulse Output
- Protection
- Power Reversal Protection
- Isolation Voltage 2,000 VDC
- Environment
- Operating Temperature -10 ~ 70° C
- Storage Temperature -20 ~ 80° C
- Humidity (Operating) 20 ~ 95% RH (non-condensing)
- Humidity (Storage) 0 ~ 95% RH (non-condensing)
Empfohlenes Zubehör
Kundenrezensionen
6 digitale Eingänge, 6 Relaisausgänge (AC: 250V@5A, DC:30V@5A)
ADAM-6066’s six digital output channels are designed for 240 V AC, 5 A ratings, and support both dry contact and pulse output. Besides, ADAM-6066 has an embedded web server for remote monitoring, supports Modbus/TCP and UDP protocol to meet standard communication requirements, and offers personalized settings for improved flexibility. Its watchdog timer and host idle functions secure communication for reliable operation.
- General
- LAN 10/100Base-T(X)
- Power Consumption 2.5 W @ 24 VDC
- Connectors 1 x RJ-45 (LAN), Plug-in screw terminal block (I/O and power)
- Watchdog Timer System (1.6 second) and Communication (programmable)
- Power Input 10 ~ 30 VDC
- Supports Peer-to-Peer
- Supports GCL
- Supports Modbus/TCP, TCP/IP, UDP and HTTP Protocols
- Digital Input
- Channels 6
- Dry Contact Logic level 0: close to GND
- Logic level 1: open
- Wet Contact Logic level 0 ~ 3 VDC
- Logic level 1: 10 ~ 30 VDC
- Supports 3 kHz Counter Input (32-bit + 1-bit overflow)
- Keep/Discard Counter Value when Power-off
- Supports 3 kHz Frequency Input
- Supports Inverted DI Status
- Relay Output (Form A)
- Channels 6
- Contact Rating (Resistive): 250 V @ 5 A (AC)
- 30 V @ 5 A (DC)
- Breakdown Voltage 500 VAC (50/60 Hz)
- Relay On Time 7 ms
- Relay Off Time 3 ms
- Total Switching Time 10 ms
- Insulation Resistance 1 GΩ min. at 500 VDC
- Maximum Switching 20 operations/minute
- Rate (at rated load)
- Supports Pulse Output
- Protection
- Power Reversal Protection
- Isolation Voltage 2,000 VDC
- Environment
- Operating Temperature -10 ~ 70° C
- Storage Temperature -20 ~ 80° C
- Humidity (Operating) 20 ~ 95% RH (non-condensing)
- Humidity (Storage) 0 ~ 95% RH (non-condensing)